OMRON MC-720 Forehead Non Contact Thermometer(White) | Zipri.in
OMRON MC-720 Forehead Non Contact Thermometer(White)

OMRON MC-720 Forehead Non Contact Thermometer(White)

Quick Overview

Rs.2990 on FlipkartBuy
Product Price Comparison
GENTLE NON INTRUSIVE TEMPERATURE MEASUREMENT1 SECOND QUICK MEASUREMENT2 MODE - SILENT & BUZZER-BEEPLAST READING RECALLTOUCH FREE, EASY TO USEBACK LIGHT FOR EASY READING25 MEMORIES STORAGELCD SCREEN2.1 Removing the Insulating TapeWhen using the thermometer for the first time, pull theinsulating tape out of the battery compartment.The unit is turned on and after 1 minute the room temperatureappears on the display.Notes:• The room temperature remains on the display even after the unit turns off.• Place the unit on a level surface, in a place that is at room temperature (away from direct sunlight or air conditioning, etc.).2.2 Switching between °C and °FThis unit is set in °C as default.1. While the room temperature is displayed, press and hold the START button.2. While holding it down, press and hold the ON/MEMbutton until °F appears on the display with two beeps.Notes:• To select °C mode again, start from step1.• When the unit is switched between °C and °F, all the readings stored in thememory are deleted.Taking a ReadingForehead Measurement ModeThis mode displays the oral-equivalent value of the measured forehead temperature.Always make sure the probe lens is clean and undamaged, and the forehead is clean with no sweat, cosmetics,scars, etc.Prior to measurement, ensure that the patient has not taken a bath or exercised within the last 30 minutes, andhas remained in a stable environment for at least 5 minutes.It is recommended to perform measurement three times. If the three measurements are different, select thehighest temperature.1. Pull off the probe lens cap to remove it.2. Press the ON/MEM button.All indicators appear on the display for 1 second.Then the display shown on the far right appears with two beeps.3. Hold the probe lens 1 to 3 cm away from the center of theforehead.Notes:• Holding the unit too long in the hand may cause a higher ambient temperature reading of theprobe. This could make the body temperature measurement lower than usual.• Keep still during measurement.4. Press the START button.The measurement is complete in 1 second with a long beep.5. Move the unit away from the forehead and check themeasurement result.The display lights up for 5 seconds.Notes:• If the result is higher than 42.2°C (108.0°F), “Hi” appears on the display.If the result is lower than 34.0°C (93.2°F), “Lo” appears on the display.• You can take another measurement after the display light turns off with twobeeps. Make sure the “ ” icon remains lit.• After the second measurement, the first measurement is displayed in the rightcorner, while the second is displayed in the center.6. Press and hold the ON/MEM button until “OFF” appears on the display toturn off the unit.The unit stores the measurement in memory, then turns off with the room temperature on the display.The unit also turns off automatically if no operation is performed for 1 minute.